Weidmüller Intermediate Relay

Jul 15, 2025 Leave a message

info-554-236

 

A relay is an automatic electrical device that connects or disconnects a control circuit according to changes in electrical quantities (such as voltage, current, etc.) or non-electrical quantities (such as heat, time, pressure, speed, etc.) to achieve automatic control, detection, protection and regulation of power systems and electric traction devices. It is actually an "automatic switch" that uses a smaller current to control a larger current. A relay is a small-capacity electrical device (generally less than 5A), which generally does not have an arc extinguishing device and cannot be used to connect and disconnect load circuits; a contactor can be used to control large-capacity circuits or electrical equipment, has good arc extinguishing measures, and can completely disconnect load circuits. The input quantity of a relay can be either an electrical quantity or a non-electrical quantity; while the input quantity of a contactor can only be voltage.

 

The definition of a relay is: a device that can generate a jump in one or more electrical output circuits when the input quantity (or excitation quantity) meets certain specified conditions. It is generally composed of three basic parts: a sensing mechanism, an intermediate mechanism, and an actuator. The sensing mechanism transmits the sensed electrical or non-electrical quantity to the intermediate mechanism, and compares it with the set setting value. When the setting value (over or under) is reached, the intermediate mechanism activates the actuator to connect or disconnect the controlled circuit.

 

 

Weidmüller Intermediate Relay

 

info-262-219

 

 

Intermediate relay selection:

 

Geographical location climate factors

Mainly refers to factors such as altitude, ambient temperature, humidity, and electromagnetic interference. Considering the universal applicability of the control system and the particularity of long-term reliable operation, the key parts of the device must use fully sealed (metal cover sealed or plastic sealed, metal cover sealed products are better than plastic sealed products) intermediate relay products with high insulation and strong electrical resistance. Because only fully sealed relays have excellent long-term tolerance to harsh environments, good electrical contact stability, reliability and load switching capacity (not affected by external climate environment).

 

Mechanical action elements

Mainly refers to stress factors such as vibration, impact, collision, etc. For the control system, the main consideration is the ability to resist earthquake stress and mechanical stress, and it is advisable to use a small intermediate relay with a balanced armature mechanism.

 

Excitation coil input parameter elements

Mainly refers to over-excitation, under-excitation, low-voltage excitation and high-voltage (220V output isolation, temperature change influence, long-distance wired excitation, electromagnetic interference excitation and other parameter elements, which are all factors that must be seriously considered to ensure the reliable operation of power system automation devices. Excitation according to the excitation amount specified by the small intermediate relay is a necessary condition to ensure its reliable and stable operation.

 

Contact output (switching circuit) parameter elements

It mainly refers to the properties of contact load, such as lamp load, capacitive load, motor load, inductor, contactor (relay) coil load, resistive load, etc.; contact load value (open circuit voltage value, closed circuit current value), such as low-level load, thousand-circuit load, small current load, large current load, etc.