Weidmuller PRO TOP1 480W 24V 20A 2466890000
Weidmuller PRO TOP1 480W 24V 20A Power supply, switch-mode power supply unit, 24 V
General ordering data
|
Version |
Power supply, switch-mode power supply unit, 24 V |
|
Order No. |
2466890000 |
|
Type |
PRO TOP1 480W 24V 20A |
|
GTIN (EAN) |
4050118481471 |
|
Qty. |
1 items |
Dimensions and weights
|
Depth |
125 mm |
|
Depth (inches) |
4.921 inch |
|
Height |
130 mm |
|
Height (inches) |
5.118 inch |
|
Width |
68 mm |
|
Width (inches) |
2.677 inch |
|
Net weight |
1,520 g |
Temperatures
|
Storage temperature |
-40 °C...85 °C |
|
Operating temperature |
-25 °C...70 °C |
|
Humidity at operating temperature |
5...95 %, no condensation |
|
Start-up |
≥ -40 °C |
Environmental Product Compliance
|
RoHS Compliance Status |
Compliant with exemption |
|
RoHS Exemption (if applicable/known) |
6c, 7a, 7cI |
|
REACH SVHC |
Lead 7439-92-1 |
|
SCIP |
6d8cdf22-8230-4af8-86c8-3558c716666d |
Input
|
AC input voltage range |
85…277 V AC |
|
Connection system |
PUSH IN |
|
Current consumption in relation to the input voltage |
Voltage type: AC Input voltage: 100 V Input current: 6 A Voltage type: DC Input voltage: 120 V Input current: 6 A |
|
DC input voltage range |
80 ... 410 V DC |
|
Frequency range AC |
45…65 Hz |
|
Input fuse (internal) |
Yes |
|
Inrush current |
max. 5 A |
|
Nominal power consumption |
516.1 VA |
|
Rated input voltage |
110...240 V AC / 120...340 V DC |
|
Recommended back-up fuse |
8 A (DI) / 10 A (Char. B), 8 A (Char. C) |
|
Surge protection |
Varistor |
Output
|
Connection system |
PUSH IN |
|
DCL - peak load reserve |
Boost duration: 5 s Multiple of the rated current: 150 % Boost duration: 15 ms Multiple of the rated current: 500 % |
|
Mains failure bridge-over time |
> 20 ms @ 115V AC/ 230 VAC |
|
Nominal output current for Unom |
20 A @ 60 °C |
|
Output power |
480 W |
|
Output voltage, max. |
28.8 V |
|
Output voltage, min. |
22.5 V |
|
Output voltage, note |
adjustable with potentiometer or comunication module |
|
Parallel connection option |
Yes, for redundancy and power increase (with ORing MOSFET) |
|
Protection against inverse voltage |
Yes |
|
Ramp-up time |
≤ 100 ms |
|
Rated output voltage |
24 V DC ± 1 % |
|
Residual ripple, breaking spikes |
<50 mVss @ UNenn, Full Load |
General data
|
AC failure bridging time @ Inom |
> 20 ms @ 230 V AC / > 20 ms @ 115 V AC |
|
Conformal coating |
No |
|
Degree of efficiency |
93% |
|
Derating |
> 60°C (2.5% / 1°C) |
|
Earth leakage current, max. |
3.5 mA |
|
Housing version |
Metal, corrosion resistant |
|
MTBF |
According to Standard: SN 29500 Operating time (hours), min.: 1,200,000 h Ambient temperature: 25 °C Input voltage: 230 V Output power: 480 W Duty cycle: 100 % According to Standard: SN 29500 Operating time (hours), min.: 562,000 h Ambient temperature: 40 °C Input voltage: 230 V Output power: 480 W Duty cycle: 100 % |
|
Power factor (approx.) |
> 0.9 |
|
Power loss, idling |
10 W |
|
Power loss, nominal load |
36.1 W |
|
Protection degree |
IP20 |
|
Short-circuit protection |
Yes |
|
Surge voltage category |
III |
EMC / shock / vibration
|
Interference immunity test acc. to |
EN 55032:2015 |
|
Noise emission in accordance with EN55032 |
Class B |
|
Shock resistance IEC 60068-2-27 |
30 g in all directions |
|
Vibration resistance IEC 60068-2-6 |
2.3 g (on DIN rail) |
Insulation coordination
|
Insulation voltage input / earth |
3.2 kV |
|
Insulation voltage output / earth |
0.5 kV |
|
Insulation voltage, input/output |
3.5 kV |
|
Pollution severity |
2 |
|
Protection class |
I, with PE connection |
|
Surge voltage category |
III |
Electrical safety (applied standards)
|
Electrical machine equipment |
Acc. to EN60204 |
|
For use with electronic equipment |
Acc. to EN50178 / VDE0160 |
|
Protection against dangerous shock currents |
Acc. to VDE0106-101 |
|
Protective separation / protection against electrical shock |
VDE0100-410 / acc. to DIN57100-410 |
|
Safety extra-low voltage |
SELV acc. to IEC 60950-1 |
|
Safety transformers for switch-mode power supplies |
According to EN 61558-2-16 |
Connection data (input)
|
Conductor cross-section, AWG/kcmil , max. |
8 AWG |
|
Conductor cross-section, AWG/kcmil , min. |
20 AWG |
|
Conductor cross-section, flexible , min. |
0.2 mm² |
|
Conductor cross-section, rigid , max. |
10 mm² |
|
Conductor cross-section, rigid , min. |
0.2 mm² |
|
Connection system |
PUSH IN |
|
Number of terminals |
3 for L/N/PE |
|
Screwdriver blade |
0.6 x 3.5 |
|
Wire connection cross section, flexible (input), max. |
6 mm² |
Connection data (output)
|
Conductor cross-section, AWG/kcmil , max. |
8 AWG |
|
Conductor cross-section, AWG/kcmil , min. |
20 AWG |
|
Conductor cross-section, flexible , max. |
6 mm² |
|
Conductor cross-section, flexible , min. |
0.2 mm² |
|
Conductor cross-section, rigid , max. |
10 mm² |
|
Conductor cross-section, rigid , min. |
0.2 mm² |
|
Connection system |
PUSH IN |
|
Number of terminals |
5 (+ + / - - -) |
|
Screwdriver blade |
0.6 x 3.5 |
Connection data (signal)
|
Wire connection cross-section, flexible (signal), max. |
1.5 mm² |
|
Wire connection cross-section, flexible (signal), min. |
0.14 mm² |
|
Wire connection method |
PUSH IN |
|
Wire cross-section, AWG/kcmil , max. |
16 |
|
Wire cross-section, AWG/kcmil , min. |
26 mm² |
|
Wire cross-section, solid , max. |
1.5 mm² |
|
Wire cross-section, solid , min. |
0.14 mm² |
Signalling
|
Floating contact |
Yes |
|
LED green/red |
Green: Operation (failure-free) |
|
Status relay (max. load) |
Output voltage OK (30 V DC / 1 A) |