Moxa TCF-142-S-SC-T RS-232/422/485 to fiber converters
Features and Benefits
- Ring and point-to-point transmission
- Extends RS-232/422/485 transmission up to 40 km with single-mode (TCF- 142-S) or 5 km with multi-mode (TCF-142-M)
- Decreases signal interference
- Protects against electrical interference and chemical corrosion
- Supports baudrates up to 921.6 kbps
- Wide-temperature models available for -40 to 75°C environments
Introduction
Moxa TCF-142-S-SC-T media converters are equipped with a multiple interface circuit that can handle RS-232 or RS-422/485 serial interfaces and multi- mode or single-mode fiber. Moxa TCF-142-S-SC-T converters are used to extend serial transmission up to 5 km (TCF-142-M with multi-mode fiber) or up to 40 km (TCF-142-S with single-mode fiber). Moxa TCF-142-S-SC-T converters can be configured to convert either RS-232 signals, or RS-422/485 signals, but not both at the same time.
Automatic Baudrate Detection
Moxa TCF-142-S-SC-T converters can automatically detect the serial baudrate, which is an extremely convenient feature. Even if a device's baudrate is changed, the signal will still be transmitted through the media converter without any data loss.
Ring Operation
Moxa TCF-142-S-SC-T converters can be used to connect serial devices to a fiber ring. To form the ring, connect the Tx port of one TCF-142-S-SC-T to the Rx port of a neighboring converter. Once the ring is set up, simply use the DIP switches to configure the TCF-142-S-SC-T converters for ring mode. When one node transmits a signal, the signal travels around the ring until it returns back to the transmitting unit, which then blocks the signal. With the TCF-142-S-SC-T, you can set up fiber rings that have a total circumference of up to 100 km.
Automatic Data Direction Control
Automatic Data Direction Control (ADDC) is a hardware data flow solution developed by Moxa to handle RS-485 data direction control. ADDC senses and controls RS-485 data direction automatically, making it unnecessary to use the handshaking signal.
Specifications
Serial Interface
|
No. of Ports |
2 |
||||||||||||||||||||||||||||||||||||||||
|
Serial Standards |
RS-232 |
||||||||||||||||||||||||||||||||||||||||
|
Baudrate |
50 bps to 921.6 kbps (supports non-standard baudrates) |
||||||||||||||||||||||||||||||||||||||||
|
Flow Control |
ADDC (automatic data direction control) for RS-485 |
||||||||||||||||||||||||||||||||||||||||
|
Optical Fiber |
|
||||||||||||||||||||||||||||||||||||||||
|
Pull High/Low Resistor for RS-485 |
1 kilo-ohm, 150 kilo-ohms |
||||||||||||||||||||||||||||||||||||||||
|
RS-485 Data Direction Control |
ADDC (automatic data direction control) |
||||||||||||||||||||||||||||||||||||||||
|
Terminator for RS-485 |
N/A, 120 ohms, 120 kilo-ohms |
||||||||||||||||||||||||||||||||||||||||
|
Connector |
7-pin terminal block |
||||||||||||||||||||||||||||||||||||||||
|
Latency |
300 ns |
||||||||||||||||||||||||||||||||||||||||
Serial Signals
|
RS-232 |
TxD, RxD, GND |
|
RS-422 |
Tx+, Tx-, Rx+, Rx-, GND |
|
RS-485-4w |
Tx+, Tx-, Rx+, Rx-, GND |
|
RS-485-2w |
Data+, Data-, GND |
Power Parameters
|
No. of Power Inputs |
1 |
|
Input Current |
70 to 140 mA @ 12 to 48 VDC |
|
Input Voltage |
12 to 48 VDC |
|
Overload Current Protection |
Supported |
|
Power Connector |
Terminal block |
|
Power Consumption |
70 to 140 mA @ 12 to 48 VDC |
|
Reverse Polarity Protection |
Supported |
Physical Characteristics
|
IP Rating |
IP30 |
|
Housing |
Metal |
|
Dimensions (with ears) |
90 x 100 x 22 mm (3.54 x 3.94 x 0.87 in) |
|
Dimensions (without ears) |
67 x 100 x 22 mm (2.64 x 3.94 x 0.87 in) |
|
Weight |
320 g (0.71 lb) |
|
Installation |
Wall mounting |
Environmental Limits
|
Operating Temperature |
Standard Models: 0 to 60°C (32 to 140°F) Wide Temp. Models: -40 to 75°C (-40 to 167°F) |
|
Storage Temperature (package included) |
-40 to 85°C (-40 to 185°F) |
|
Ambient Relative Humidity |
5 to 95% (non-condensing) |
Standards and Certifications
|
EMC |
EN 55032/35 |
|
EMI |
CISPR 32, FCC Part 15B Class A |
|
EMS |
IEC 61000-4-2 ESD: Contact: 4 kV; Air: 8 kV IEC 61000-4-3 RS: 80 MHz to 1 GHz: 10 V/m IEC 61000-4-4 EFT: Power: 1 kV IEC 61000-4-5 Surge: Power: 1 kV IEC 61000-4-6 CS: 3 V IEC 61000-4-8 PFMF |
|
Environmental Testing |
IEC 60068-2-1 IEC 60068-2-2 IEC 60068-2-3 |
|
Safety |
UL 60950-1 |
|
Vibration |
IEC 60068-2-6 |
MTBF
|
Time |
780,480 hrs |
|
Standards |
Telcordia (Bellcore), GB |
Package Contents
|
Device |
1 x TCF-142 Series converter |
|
Installation Kit |
1 x rubber stand |
|
Documentation |
1 x quick installation guide 1 x warranty card |
Dimensions
![]() |
Ordering Information
|
Model Name |
Operating Temp. |
Fiber Module Type |
|
TCF-142-M-ST |
0 to 60°C |
Multi-mode ST |
|
TCF-142-M-SC |
0 to 60°C |
Multi-mode SC |
|
TCF-142-S-ST |
0 to 60°C |
Single-mode ST |
|
TCF-142-S-SC |
0 to 60°C |
Single-mode SC |
|
TCF-142-M-ST-T |
-40 to 75°C |
Multi-mode ST |
|
TCF-142-M-SC-T |
-40 to 75°C |
Multi-mode SC |
|
TCF-142-S-ST-T |
-40 to 75°C |
Single-mode ST |
|
TCF-142-S-SC-T |
-40 to 75°C |
Single-mode SC |
Accessories (sold separately)
DIN-Rail Mounting Kits
|
DK35A |
DIN-rail mounting kit, 35 mm |
Power Adapters
|
PWR-12150-WPUSJP-S2 |
Unlocking barrel plug, 12 VDC, 1.5 A, 100 to 240 VAC, US/JP plug, 0 to 40°C operating temperature |
|
PWR-12150-WPAU-S2 |
Unlocking barrel plug, 12 VDC, 1.5 A, 100 to 240 VAC, AU plug, 0 to 40°C operating temperature |
|
PWR-12150-WPEU-S2 |
Unlocking barrel plug, 12 VDC, 1.5 A, 100 to 240 VAC, EU plug, 0 to 40°C operating temperature |
|
PWR-12150-WPUK-S2 |
Unlocking barrel plug, 12 VDC, 1.5 A, 100 to 240 VAC, UK plug, 0 to 40°C operating temperature |
|
PWR-12150-WPCN-S2 |
Unlocking barrel plug, 12 VDC, 1.5 A, 100 to 240 VAC, CN plug, 0 to 40°C operating temperature |
Power Cords
|
CBL-PJTB-10 |
Non-locking barrel plug to bare-wire cable |
Hot Tags: moxa tcf-142-s-sc-t, China, wholesale, online, order, p206a, nport 5230 moxa, inj 24a, Moxa EDS G205 1GTXSFP T, nport 5650 16, uport 1100