Instructions for Using the DIP Switch of Moxa Unmanaged Switches

Apr 18, 2025 Leave a message

1.EDS-205A\208A

The dip switch is shown in the figure below:

The function of switch 1 is broadcast storm protection. When it is turned on, it can prevent broadcast storms caused by misconnected loops, which may lead to network failures.

Switch 2 has no function.

info-554-330

2. EDS-305\308\309

The dip switch is shown in the figure below:

Each switch corresponds to the fault alarm function of each port. When this function is turned on, if the link of the port fails, the relay will form an open circuit and the fault LED will light up.

info-554-276info-554-168

3. EDS-316

The dip switch is shown in the figure below:

P1~P16 are the port alarm functions of ports 1~16. When this function is enabled, if the link of the port fails, the relay will be open and the fault LED will light up.

BSP is broadcast storm protection. When it is turned on, it can prevent broadcast storms caused by misconnected loops and cause network failures.

 

info-554-198