Weidmuller PRO ECO3 120W 24V 5A 1469530000
Weidmuller PRO ECO3 120W 24V 5A 1469530000 power supply, switch-mode power supply unit, 24 V
General ordering data
|
Version |
Power supply, switch-mode power supply unit, 24 V |
|
Order No. |
1469530000 |
|
Type |
PRO ECO3 120W 24V 5A |
|
GTIN (EAN) |
4050118275735 |
|
Qty. |
1 items |
|
Delivery status |
This article will no longer be available in the future. |
|
Available until |
30.12.2026 |
|
Alternative product |
3025620000 |
Dimensions and weights
|
Depth |
100 mm |
|
Depth (inches) |
3.937 inch |
|
Height |
125 mm |
|
Height (inches) |
4.921 inch |
|
Width |
40 mm |
|
Width (inches) |
1.575 inch |
|
Net weight |
677 g |
Temperatures
|
Storage temperature |
-40 °C...85 °C |
|
Operating temperature |
-25 °C...70 °C |
Environmental Product Compliance
|
RoHS Compliance Status |
Compliant with exemption |
|
RoHS Exemption (if applicable/known) |
7a, 7cI |
|
REACH SVHC |
Lead 7439-92-1 |
|
SCIP |
6d8cdf22-8230-4af8-86c8-3558c716666d |
Input
|
AC input voltage range |
3 x 320...3 x 575 V AC / 2 x 360...2 x 575 V AC |
|
Connection system |
Screw connection |
|
Current consumption in relation to the input voltage |
Voltage type: 3-phase AC Input voltage: 400 V Input current: 0.4 A Voltage type: 3-phase AC Input voltage: 500 V Input current: 0.3 A Voltage type: DC Input voltage: 800 V Input current: 0.2 A Voltage type: DC Input voltage: 450 V Input current: 0.4 A |
|
DC input voltage range |
450...800 V DC |
|
Frequency range AC |
47...63 Hz |
|
Input electric strength, max. |
AC/DC |
|
Input fuse (internal) |
Yes |
|
Inrush current |
max. 40 A |
|
Nominal power consumption |
137.9 VA |
|
Rated input voltage |
3x 400...3x 500 V AC (wide-range input) |
|
Recommended back-up fuse |
2 A / DI, safety fuse |
|
Surge protection |
Varistor |
Output
|
Capacitive load |
unrestricted |
|
Connection system |
Screw connection |
|
Continuous output current @ UNominal |
5 A @ 55 °C |
|
Nominal output current for Unom |
5 A at 55 °C |
|
Output power |
120 W |
|
Output voltage, max. |
28 V |
|
Output voltage, min. |
22 V |
|
Output voltage, note |
(adjustable via potentiometer) |
|
Overload protection |
Yes |
|
Parallel connection option |
yes, max. 5 |
|
Protection against inverse voltage |
Yes |
|
Ramp-up time |
≤ 100 ms |
|
Rated output voltage |
24 V DC ± 1 % |
|
Residual ripple, breaking spikes |
<50 mVPP @ 24 V DC, IN |
General data
|
AC failure bridging time @ Inom |
> 40 ms @ 3 x 500 V AC / > 20 ms @ 3 x 400 V AC |
|
Degree of efficiency |
87 % |
|
Earth leakage current, max. |
3.5 mA |
|
Housing version |
Metal, corrosion resistant |
|
Indication |
Green LED (Uoutput > 21.6 V DC) |
|
Max. perm. air humidity (operational) |
5 %…95 % RH |
|
Mounting position, installation notice |
on terminal rail TS 35 |
|
MTBF |
According to Standard: SN 29500 Operating time (hours), min.: 2,500,000 h Ambient temperature: 25 °C Input voltage: 400 V Output power: 120 W Duty cycle: 100 % According to Standard: SN 29500 Operating time (hours), min.: 1,100,000 h Ambient temperature: 40 °C Input voltage: 400 V Output power: 120 W Duty cycle: 100 % |
|
Power factor (approx.) |
> 0.55 @ 3 x 500 V AC / > 0.65 @ 3 x 400 V AC |
|
Power loss, idling |
6 W |
|
Power loss, nominal load |
17 W |
|
Protection against over-heating |
Yes |
|
Protection against reverse voltages from the load |
30…35 V DC |
|
Protection degree |
IP20 |
|
Short-circuit protection |
Yes |
|
Surge voltage category |
II |
EMC / shock / vibration
|
Interference immunity test acc. to |
EN 61000-4-2 (ESD) |
|
Limiting of mains voltage harmonic currents |
According to EN 61000-3-2 |
|
Noise emission in accordance with EN55032 |
Class B |
|
Shock resistance IEC 60068-2-27 |
15 g In all directions |
|
Vibration resistance IEC 60068-2-6 |
1 g according to EN 50178 |
Insulation coordination
|
Insulation voltage input / earth |
2 kV |
|
Insulation voltage output / earth |
0.5 kV |
|
Insulation voltage, input/output |
3 kV |
|
Pollution severity |
2 |
|
Protection class |
I, with PE connection |
|
Surge voltage category |
II |
Electrical safety (applied standards)
|
Electrical machine equipment |
Acc. to EN60204 |
|
For use with electronic equipment |
Acc. to EN50178 / VDE0160 |
|
Protection against dangerous shock currents |
Acc. to VDE0106-101 |
|
Protective separation / protection against electrical shock |
VDE0100-410 / acc. to DIN57100-410 |
|
Safety extra-low voltage |
SELV acc. to IEC 60950-1 |
|
Safety transformers for switch-mode power supplies |
According to EN 61558-2-16 |
Connection data (input)
|
Conductor cross-section, AWG/kcmil , max. |
12 AWG |
|
Conductor cross-section, AWG/kcmil , min. |
26 AWG |
|
Conductor cross-section, flexible , min. |
0.5 mm² |
|
Conductor cross-section, rigid , max. |
6 mm² |
|
Conductor cross-section, rigid , min. |
0.5 mm² |
|
Connection system |
Screw connection |
|
Number of terminals |
4 for L1/L2/L3/PE |
|
Tightening torque, max. |
0.6 Nm |
|
Tightening torque, min. |
0.5 Nm |
|
Wire connection cross section, flexible (input), max. |
2.5 mm² |
Connection data (output)
|
Conductor cross-section, AWG/kcmil , max. |
12 AWG |
|
Conductor cross-section, AWG/kcmil , min. |
26 AWG |
|
Conductor cross-section, flexible , max. |
2.5 mm² |
|
Conductor cross-section, flexible , min. |
0.5 mm² |
|
Conductor cross-section, rigid , max. |
6 mm² |
|
Conductor cross-section, rigid , min. |
0.5 mm² |
|
Connection system |
Screw connection |
|
Number of terminals |
6 (++,--,13,14) |
|
Tightening torque, max. |
0.6 Nm |
|
Tightening torque, min. |
0.5 Nm |
Signalling
|
Contact load (NO contact) |
max. 30 V DC / 1 A |
|
Floating contact |
Yes |
|
Relay on/off |
Output voltage >21.6 V DC/ <20.4 V DC, overload |