Weidmuller PRO ECO 480W 24V 20A 1469510000
General ordering data
|
Version |
Power supply, switch-mode power supply unit, 24 V |
|
Order No. |
1469510000 |
|
Type |
PRO ECO 480W 24V 20A |
|
GTIN (EAN) |
4050118275483 |
|
Qty. |
1 pc(s). |
Dimensions and weights
|
Depth |
120 mm |
|
Depth (inches) |
4.724 inch |
|
Height |
125 mm |
|
Height (inches) |
4.921 inch |
|
Width |
100 mm |
|
Width (inches) |
3.937 inch |
|
Net weight |
1,557 g |
Temperatures
|
Storage temperature |
-40 °C...85 °C |
|
Operating temperature |
-25 °C...70 °C |
Environmental Product Compliance
|
RoHS Compliance Status |
Compliant with exemption |
|
RoHS Exemption (if applicable/known) |
7a, 7cI |
|
REACH SVHC |
Lead 7439-92-1 |
|
SCIP |
6d8cdf22-8230-4af8-86c8-3558c716666d |
Input
|
AC current consumption |
2,37 A @ 230 V AC / 5,2 A @ 110 V AC |
|
AC input voltage range |
85...264 V AC (derating at 100 V AC) |
|
Connection system |
Screw connection |
|
DC current consumption |
1,55 A @ 370 V DC / 4,65 A @ 120 V DC |
|
DC input voltage range |
80...370 V DC (Derating @ 120 V DC) |
|
Frequency range AC |
47...63 Hz |
|
Input fuse (internal) |
Yes |
|
Inrush current |
max. 5 A |
|
Nominal power consumption |
527.5 VA |
|
Rated input voltage |
100...240 V AC |
|
Recommended back-up fuse |
6 A / DI, safety fuse |
|
Surge protection |
Varistor |
Output
|
Capacitive load |
unrestricted |
|
Connection system |
Screw connection |
|
Continuous output current @ UNominal |
20 A @ 55 °C, 15 A @ 70 °C |
|
Nominal output current for Unom |
20 A @ 55 °C |
|
Output power |
480 W |
|
Output voltage, max. |
28 V |
|
Output voltage, min. |
22 V |
|
Output voltage, note |
(adjustable via potentiometer) |
|
Overload protection |
Yes |
|
Parallel connection option |
yes, max. 3 |
|
Protection against inverse voltage |
Yes |
|
Ramp-up time |
≤ 100 ms |
|
Rated output voltage |
24 V DC ± 1 % |
|
Residual ripple, breaking spikes |
<50 mVPP @ 24 V DC, IN |
General data
|
AC failure bridging time @ Inom |
> 20 ms @ 230 V AC / > 20 ms @ 115 V AC |
||||||||||||||||||||||||||
|
Degree of efficiency |
91% |
||||||||||||||||||||||||||
|
Earth leakage current, max. |
3.5 mA |
||||||||||||||||||||||||||
|
Housing version |
Metal, corrosion resistant |
||||||||||||||||||||||||||
|
Indication |
Green LED (Uoutput > 21.6 V DC), Yellow LED (loutput > 90 % IRated typ. ), red LED (overload, overtemperature, short-circuit, Uoutput <20.4 V DC) |
||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||
|
Max. perm. air humidity (operational) |
5 %…95 % RH |
||||||||||||||||||||||||||
|
Mounting position, installation notice |
on terminal rail TS 35 |
||||||||||||||||||||||||||
|
Power factor (approx.) |
> 0.98…230 V AC / > 0.98…115 V AC |
||||||||||||||||||||||||||
|
Power loss, idling |
5 W |
||||||||||||||||||||||||||
|
Power loss, nominal load |
43 W |
||||||||||||||||||||||||||
|
Protection against over-heating |
Yes |
||||||||||||||||||||||||||
|
Protection against reverse voltages from the load |
30…35 V DC |
||||||||||||||||||||||||||
|
Protection degree |
IP20 |
||||||||||||||||||||||||||
|
Short-circuit protection |
Yes |
||||||||||||||||||||||||||
|
Surge voltage category |
II |
||||||||||||||||||||||||||
EMC / shock / vibration
|
Interference immunity test acc. to |
EN 61000-4-2 (ESD), EN 61000-4-3 (RS), EN 61000-4-4 (burst), EN 61000-4-5 (surge), EN 61000-4-6 (conducted), EN61000-4-8 (Fields), EN61000-4-11 (Dips) |
|
Limiting of mains voltage harmonic currents |
According to EN 61000-3-2 |
|
Noise emission in accordance with EN55032 |
Class B |
|
Shock resistance IEC 60068-2-27 |
15 g In all directions |
|
Vibration resistance IEC 60068-2-6 |
1 g according to EN 50178 |
Insulation coordination
|
Insulation voltage input / earth |
2 kV |
|
Insulation voltage output / earth |
0.5 kV |
|
Insulation voltage, input/output |
3 kV |
|
Pollution severity |
2 |
|
Protection class |
I, with PE connection |
|
Surge voltage category |
II |
Electrical safety (applied standards)
|
Electrical machine equipment |
Acc. to EN60204 |
|
For use with electronic equipment |
Acc. to EN50178 / VDE0160 |
|
Protection against dangerous shock currents |
Acc. to VDE0106-101 |
|
Protective separation / protection against electrical shock |
VDE0100-410 / acc. to DIN57100-410 |
|
Safety extra-low voltage |
SELV acc. to IEC 60950-1, PELV according to EN 60204-1 |
|
Safety transformers for switch-mode power supplies |
According to EN 61558-2-16 |
Connection data (input)
|
Conductor cross-section, AWG/kcmil , max. |
12 AWG |
|
Conductor cross-section, AWG/kcmil , min. |
26 AWG |
|
Conductor cross-section, flexible , min. |
0.5 mm² |
|
Conductor cross-section, rigid , max. |
6 mm² |
|
Conductor cross-section, rigid , min. |
0.5 mm² |
|
Connection system |
Screw connection |
|
Number of terminals |
3 for L/N/PE |
|
Tightening torque, max. |
0.6 Nm |
|
Tightening torque, min. |
0.5 Nm |
|
Wire connection cross section, flexible (input), max. |
2.5 mm² |
Connection data (output)
|
Conductor cross-section, AWG/kcmil , max. |
10 AWG |
|
Conductor cross-section, AWG/kcmil , min. |
26 AWG |
|
Conductor cross-section, flexible , max. |
2.5 mm² |
|
Conductor cross-section, flexible , min. |
0.5 mm² |
|
Conductor cross-section, rigid , max. |
6 mm² |
|
Conductor cross-section, rigid , min. |
0.5 mm² |
|
Connection system |
Screw connection |
|
Number of terminals |
7 (++,---,13,14) |
|
Tightening torque, max. |
0.6 Nm |
|
Tightening torque, min. |
0.5 Nm |
Signalling
|
Contact load (NO contact) |
max. 30 V DC / 1 A |
|
Floating contact |
Yes |
|
Relay on/off |
Output voltage >21.6 V DC/ <20.4 V DC, overload |
Hot Tags: weidmuller pro eco 480w 24v 20a 1469510000, China, wholesale, online, order, weidmuller safety relay, thm mmp weidmuller, weidmuller connector, 1689990000, weidmuller wpe 6, weidmuller 1021500000