Weidmuller IE-SW-AL10M-8TX-2GC 2740420000

Weidmuller IE-SW-AL10M-8TX-2GC 2740420000

Weidmuller IE-SW-AL10M-8TX-2GC Network switch, managed, Fast/Gigabit Ethernet, Number of ports: 8x RJ45 10/100BaseT(X), 2x combo-ports (10/100/1000BaseT(X) or 100/1000BaseSFP), IP30, -40 °C...75 °C
Send Inquiry

Weidmuller IE-SW-AL10M-8TX-2GC 2740420000

 

Weidmuller IE-SW-AL10M-8TX-2GC Network switch, managed, Fast/Gigabit Ethernet, Number of ports: 8x RJ45 10/100BaseT(X), 2x combo-ports (10/100/1000BaseT(X) or 100/1000BaseSFP), IP30, -40 °C...75 °C

 

General ordering data

Version

Network switch, managed, Fast/Gigabit Ethernet, Number of ports: 8x RJ45 10/100BaseT(X), 2x combo-ports (10/100/1000BaseT(X) or 100/1000BaseSFP), IP30, -40 °C...75 °C

Order No.

2740420000

Type

IE-SW-AL10M-8TX-2GC

GTIN (EAN)

4050118835830

Qty.

1 items

 

Dimensions and weights

Depth

107.5 mm

Depth (inches)

4.232 inch

Height

153.6 mm

Height (inches)

6.047 inch

Width

74.3 mm

Width (inches)

2.925 inch

Net weight

1,159 g

 

Temperatures

Storage temperature

-40 °C...85 °C

Operating temperature

-40 °C...75 °C

Humidity

5 to 95 % (non-condensing)

 

Environmental Product Compliance

RoHS Compliance Status

Compliant with exemption

RoHS Exemption (if applicable/known)

6c, 7a, 7cI

REACH SVHC

Lead 7439-92-1
Lead monoxide 1317-36-8

SCIP

9229992a-00b9-4096-8962-200a7f33e289

 

EMC conformity and approvals

EMC standards

EN 55032
EN 55024
FCC Part 15 Subpart B Class A
IEC 61000-4-2 ESD: Contact: 4 kV; Air: 8 kV
IEC 61000-4-3 RS: 80 MHz bis 1 Ghz: 3 V/m
IEC 61000-4-4 EFT: Power: 0.5 kV; Signal: 0.5 kV
IEC 61000-4-5 Surge: Power: 0,5 kV; Signal: 1 kV
IEC 61000-4-6 CS: 3 Vrms

Free fall

According to IEC 60068-2-31

Safety standard

UL 61010-1
UL 61010-2-201

Shock

according to IEC 60068-2-27

Vibration

according to IEC 60068-2-6

 

Environmental conditions

Humidity

5 to 95 % (non-condensing)

Operating altitude

Altitude, max.: 2,000 m

Note: in acc. with UL

Altitude, max.: 6,000 m

Note: for restrictions, see the manufacturer's declaration for operating altitude in section downloads

Operating temperature, max.

75 °C

Operating temperature, min.

-40 °C

Storage temperature, max.

85 °C

Storage temperature, min.

-40 °C

 

Interfaces

Alarm contact

1 relay output with a current capacity of 1 A at 24 V DC

Console port interface

RS-232 (RJ45 connector)

Fibre-optic ports

100/1000Base SFP Slot

Function reset button

<5 sec: System reboot
>5 sec: Factory default

Number of ports

8x RJ45 10/100BaseT(X)
2x combo-ports (10/100/1000BaseT(X) or 100/1000BaseSFP)

RJ45 ports

10/100BaseT(X) or 10/100/1000BaseT(X)
auto negotiation
Full-/half-duplex mode
Auto MDI/MDI-X port

 

Management features

Device configuration

Webbrowser (HTTP/HTTPS)
SNMP v1/v2c/v3
Local serial console port (RS-232 via RJ-45 port)
Upload of a configuration file via web-interface or TFTP-Server
Command Line Interface (Telnet/SSH)

Monitoring function

SNMP v1/v2c/v3
Link Layer Discovery Protocol (LLDP)
Port mirroring
Port statistics
Port monitoring
Syslog
RMON (Remote monitoring)
Event based warning via E-Mail
Event based warning via relay
Event based warning via SNMP trap

Network redundancy

Spanning Tree Protocol (STP)
Rapid Spanning Tree Protocol (RSTP)
Multiple Spanning Tree Protocol (MSTP)
O-Ring (recovery time <10/30 ms at Fast/Gigabit Ethernet interface)
O-Chain (recovery time <10/30 ms at Fast/Gigabit Ethernet interface)
Link Aggregation Control Protocol (LACP)
Fast recovery

Network traffic filter

Quality of Service (QoS)
Class of Service (CoS)
Type of Service (ToS)
Differentiated Services Code Point (DSCP)
Port based VLAN
Tag based VLAN
GVRP (GARP VLAN Registration Protocol)
IGMP v2/v3
Multicast VLAN Registration (MVR)
Traffic Rate Limiting

IP-address management

Static
DHCP-Client
DHCP-Server (port based, pool-based)
DHCP Option 82
DHCP-Relay
IPv4/IPv6

Security functions

VLAN segmentation
Enable/disable ports
TACACS+ and IEEE 802.1X User Authentication
Access control (port based via IEEE 802.1X)
Access control list (IP-based)
Access control list (MAC-based)
Management access security via secure IP-list and configuration of allowed access methods (web-interface, telnet, SSH)
Loop protection

Time synchronization management

NTP server
SNTP client

Industrial protocol support

Modbus/TCP slave
PROFINET device acc. to conformance class A

 

MTBF

MTBF

According to Standard: Telcordia SR-332

Operating time (hours), min.: 366,529 h

 

Power supply

Connection type

1 removable 6-pin terminal block

Current consumption

Voltage: 12 V

Current: 0.9 A

Voltage: 24 V

Current: 0.45 A

Voltage: 48 V

Current: 0.2 A

Overload current protection

Yes

Reverse polarity protection

Yes

Voltage supply

12/24/48 V DC
2 redundant inputs

Voltage supply range

Voltage type: DC

Voltage, min.: 10.8 V

Voltage, max.: 52.8 V

 

Switch characteristics

Bandwidth backplane

5.6 Gbit/s

IGMP-Groups

1024

MAC table size

8 K

Max. number of available VLANs

4095

Packet buffer size

1 Mbit

Priority queues

4

VLAN-ID max

4094

VLAN-ID min

1

 

Technical data

Housing main material

Metal

Protection degree

IP30

Speed

Fast/Gigabit Ethernet

Switch

managed

Type of mounting

DIN rail

 

Technology

Data switching

Store and Forward

Flow control

IEEE 802.3x flow control

Standard

IEEE 802.3 for 10BASE-T
IEEE 802.3u for 100BASE-TX and 100BASE-FX
IEEE 802.1Q for VLAN tagging
IEEE 802.1X for authentication
IEEE 802.1AB for Link Layer Discovery protocol (LLDP)
IEEE 802.3ab for 1000BASE-T
IEEE 802.3z for 1000BASE-X
IEEE 802.3x for flow control
IEEE 802.3ad for port trunk with LACP
IEEE 802.1D for the Spanning Tree protocol
IEEE 802.1w for Rapid STP
IEEE 802.1s for the Multiple Spanning Tree Protocol (MSTP)
IEEE 802.1p for Class of Service

Hot Tags: weidmuller ie-sw-al10m-8tx-2gc 2740420000, China, wholesale, online, order, weidmuller ur20, hdc he 16 ms, ie sw al10m 8tx 2gc, weidmuller rss 113 024, wpe 6 weidmuller, weidmuller ask1