Phoenix Contact TRIO-PS/3AC/24DC/20 2866394
Phoenix Contact TRIO-PS/3AC/24DC/20 2866394

Phoenix Contact TRIO-PS/3AC/24DC/20 2866394

The TRIO POWER range of power supplies offers standard functionality for use in machine production. The 1- and 3-phase versions, with a power rating of up to 960 W, are suitable for use worldwide thanks to the wide-range input and international approval package.
Send Inquiry

Phoenix Contact TRIO-PS/3AC/24DC/20 Power Supply Unit 2866394

 

Product description

 

The Phoenix Contact TRIO-PS/3AC/24DC/20 primary-switched TRIO POWER power supply for DIN rail mounting, input: Three-phase output. 24 V DC/20 A

 

The TRIO POWER range of power supplies offers standard functionality for use in machine production. The 1- and 3-phase versions, with a power rating of up to 960 W, are suitable for use worldwide thanks to the wide-range input and international approval package.

Customers are given a dependable and sturdy product because of the sturdy metal housing, strong electric strength, and broad temperature range, which guarantee a high degree of power supply reliability.

 

Product features

 

The third negative terminal block can be used as a grounding terminal block, which helps to minimise installation costs. The product features a robust design with a metal housing and a wide temperature range from -25 to +70°C, making it suitable for use in a variety of environments. The product offers maximum operational reliability thanks to a high MTBF (mean time between failures) of more than 500,000 hours and a high dielectric strength of up to 300 V AC. Furthermore, the output voltage can be adjusted at the front to compensate for voltage drops.

 

Technical data

 

Input data

AC operation

Nominal input voltage range

3x 400 V AC ... 500 V AC

Input voltage range

3x 320 V AC ... 575 V AC (Derating < 360 V AC: 1,5 %/V)

2x 360 V AC ... 575 V AC (for 2-phase operation)

Extended input voltage range in operation

3x 320 V AC ... 575 V AC (Derating < 360 V AC: 1,5 %/V)

Input voltage range AC

3x 320 V AC ... 575 V AC (Derating < 360 V AC: 1,5 %/V)

2x 360 V AC ... 575 V AC (for 2-phase operation)

Voltage type of supply voltage

AC

Inrush current

< 15 A

Inrush current integral (I2t)

0.5 A2s

AC frequency range

45 Hz ... 65 Hz

Mains buffering time

> 17 ms (3x 400 V AC)

Current consumption

3x 1.1 A (400 V AC)

3x 0.8 A (480 V AC)

Nominal power consumption

793 VA

Protective circuit

Transient surge protection; Varistor

Power factor (cos phi)

0.67

Typical response time

< 1 s

Permissible backup fuse

B6 B10 B16

Recommended breaker for input protection

6 A ... 16 A (Characteristics B, C, D, K)

Discharge current to PE

< 3.5 mA

 

Output data

Efficiency

91 % (at 400 V AC and nominal values)

Output characteristic

U/I

Nominal output voltage

24 V DC ±1 %

Setting range of the output voltage (USet)

22.5 V DC 29.5 V DC (> 24 V DC, constant capacity restricted)

Nominal output current (IN)

20 A (UOUT = 24 V DC)

Derating

55 °C ... 70 °C (2.5 %/K)

Feedback voltage resistance

35 V DC

Protection against overvoltage at the output (OVP)

< 35 V DC

Max. capacitive load

unlimited

Active current limitation

Approx. 25 A

Control deviation

< 1 % (change in load, static 10 % ... 90 %)

< 2 % (change in load, dynamic 10 % ... 90 %)

< 0.1 % (change in input voltage ±10 %)

Residual ripple

< 10 mVPP

Output power

480 W

Peak switching voltages nominal load

< 30 mVPP

Maximum no-load power dissipation

< 6 W

 

Power loss nominal load max.

< 48 W

Rise time

< 2 ms (UOUT (10 % ... 90 %))

Connection in parallel

yes, for redundancy and increased capacity

Connection in series

yes

 

Connection data

Input

Connection method

Screw connection

Conductor cross section, rigid min.

0.2 mm²

Conductor cross section, rigid max.

2.5 mm²

Conductor cross section flexible min.

0.2 mm²

Conductor cross section flexible max.

2.5 mm²

Conductor cross section AWG min.

24

Conductor cross section AWG max.

14

Stripping length

9 mm

Screw thread

M2,5

Tightening torque, min

0.4 Nm

Tightening torque max

0.5 Nm

 

Output

Connection method

Screw connection

Conductor cross section, rigid min.

0.5 mm²

Conductor cross section, rigid max.

6 mm²

Conductor cross section flexible min.

0.5 mm²

Conductor cross section flexible max.

4 mm²

Conductor cross section AWG min.

12

Conductor cross section AWG max.

10

Stripping length

14 mm

Screw thread

M3

Tightening torque, min

0.5 Nm

Tightening torque max

0.6 Nm

 

Signaling

Types of signaling

LED

Operating voltage display

Green LED

Signal output

Status display

"DC OK" LED green

Note on status display

UOUT > 21.5 V: LED lights up

 

Electrical properties

Insulation voltage input/output

4 kV AC (type test)

2 kV AC (routine test)

Insulation voltage output / PE

500 V DC (routine test)

Insulation voltage input / PE

2 kV AC (type test)

 

Product properties

Product type

Power supply

Product family

TRIO POWER

MTBF (IEC 61709, SN 29500)

> 1190000 h

 

Data management status

Article revision

04

 

Insulation characteristics

Protection class

I (with PE connection)

Overvoltage category

III

Degree of pollution

2

 

Dimensions

Dimensional drawing

product-194-169

Width

115 mm

Height

130 mm

Depth

152.5 mm

 

Installation dimensions

Installation distance right/left

0 mm / 0 mm

Installation distance top/bottom

50 mm / 50 mm

 

Mounting

Assembly note

alignable: horizontally 0 mm, vertically 50 mm

Mounting position

horizontal DIN rail NS 35, EN 60715

With protective coating

no

Material specifications

Housing material

Metal

Type of housing

Steel sheet, zinc-plated

Side element version

Aluminum

 

Environmental and real-life conditions

Ambient conditions

Degree of protection

IP20

Ambient temperature (operation)

-25 °C ... 70 °C (> 55° C derating : 2.5%/K)

Ambient temperature (storage/transport)

-40 °C ... 85 °C

Climatic class

3K3 (in acc. with EN 60721)

 

Max. permissible relative humidity (operation)

≤ 95 % (at 25 °C, non-condensing)

Shock

18 ms, 30g, in each space direction (according to IEC 60068-2- 27)

Vibration (operation)

< 15 Hz, amplitude ±2.5 mm (according to IEC 60068-2-6)

15 Hz ... 150 Hz, 2.3g, 90 min.

 

Standards and regulations

Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations

EN 50178/VDE 0160 (PELV)

Standard – Limitation of mains harmonic currents

EN 61000-3-2

Standard - Electrical safety

EN 60950-1/VDE 0805 (SELV)

Standard – Protection against shock currents, basic requirements for protective separation in electrical equipment

EN 50178

Standard – Safety extra-low voltage

EN 60950-1 (SELV)

EN 60204 (PELV)

Standard - Safe isolation

DIN VDE 0100-410

 

Approvals

UL approvals

UL/C-UL listed UL 508

UL/C-UL Recognized UL 60950-1

 

Conformity/Approvals

SIL in accordance with IEC 61508

0

 

EMC data

Electromagnetic compatibility

Conformance with EMC Directive 2014/30/EU

Low Voltage Directive

Conformance with Low Voltage Directive 2014/35/EC

EMC requirements for noise emission

EN 61000-6-3

EN 61000-6-4

EMC requirements for noise immunity

EN 61000-6-1

EN 61000-6-2

 

Electrostatic discharge

Standards/regulations

EN 61000-4-2

 

Electrostatic discharge

Contact discharge

8 kV (Test Level 4)

Discharge in air

8 kV (Test Level 3)

Comments

Criterion A

 

Electromagnetic HF field

Standards/regulations

EN 61000-4-3

 

Electromagnetic HF field

Frequency range

80 MHz ... 1 GHz

Test field strength

10 V/m

Frequency range

1 GHz ... 2 GHz

 

Test field strength

10 V/m

Frequency range

2 GHz ... 3 GHz

Test field strength

10 V/m

Comments

Criterion A

 

Fast transients (burst)

Standards/regulations

EN 61000-4-4

 

Fast transients (burst)

Input

4 kV (Test Level 4 - asymmetrical)

Output

4 kV (Test Level 4 - asymmetrical)

Signal

2 kV (Test Level 3 - asymmetrical)

Comments

Criterion A

 

Surge voltage load (surge)

Standards/regulations

EN 61000-4-5

 

Surge voltage load (surge)

Input

1 kV (Test Level 2 - symmetrical)

2 kV (Test Level 3 - asymmetrical)

Output

0.5 kV (Test Level 1 - symmetrical)

0.5 kV (Test Level 1 - asymmetrical)

Comments

Criterion B

 

Conducted interference

Standards/regulations

EN 61000-4-6

 

Conducted interference

Frequency range

0.15 MHz ... 80 MHz

Comments

Criterion A

Voltage

10 V (Test Level 3)

 

Voltage dips

Standards/regulations

EN 61000-4-11

 

Emitted interference

Standards/regulations

EN 61000-6-3

Radio interference voltage in acc. with EN 55011

EN 55011 (EN 55022) Class B, area of application: Industry and residential

Emitted radio interference in acc. with EN 55011

EN 55011 (EN 55022) Class B, area of application: Industry and residential

 

Phoenix Contact 2866394 Power Supply Unit

Phoenix Contact 2866394

 

Hot Tags: phoenix contact trio-ps/3ac/24dc/20 2866394, China, wholesale, online, order, Phoenix Contact ST 2 5 3031212, phoenix contact crimpfox, Phoenix Contact WIREFOX 2 5 1212368, Phoenix Contact FL SWITCH SFNB 5TX 2891001, Phoenix Contact TRIO PS 2G1AC24DC10 2903149, Phoenix Contact CRIMPFOX CENTRUS 6S 1213144