Moxa NDR-120-24

Moxa NDR-120-24

Moxa NDR-120-24 DIN rail power supply are particularly intended for industrial applications. The power supply' tiny form factor of 40 to 63 mm allows for easy installation in small and constrained locations such as cabinets. They can operate in severe settings because to their wide working temperature range of -20°C to 70°C. The devices feature a metal casing, an AC input range of 90 VAC to 264 VAC, and comply with the EN 61000-3-2 standard. In addition, these power supply provide a constant current mode for overload prevention.
Send Inquiry

Moxa NDR-120-24 NDR DIN-rail Power Supply

 

Introduction

 

Moxa NDR-120-24 DIN rail power supply are particularly intended for industrial applications. The power supply' tiny form factor of 40 to 63 mm allows for easy installation in small and constrained locations such as cabinets. They can operate in severe settings because to their wide working temperature range of -20°C to 70°C. The devices feature a metal casing, an AC input range of 90 VAC to 264 VAC, and comply with the EN 61000-3-2 standard. In addition, these power supply provide a constant current mode for overload prevention.

 

Features and Benefits

Features include a DIN-rail mounted power supply, a slim form factor for cabinet installation, universal AC power input, and high conversion efficiency.

 

Specifications

 

Output Power Parameters

Wattage

NDR-120-24: 120W

NDR-120-48: 120W

NDR-240-48: 240 W

Voltage

NDR-120-24: 24 VDC

NDR-120-48: 48 VDC

NDR-240-48: 48 VDC

Current Rating

NDR-120-24: 0 to 5 A

NDR-120-48: 0 to 2.5 A

NDR-240-48: 0 to 5 A

Ripple and Noise

NDR-120-24: 120 mVp-p

NDR-120-48: 150 mVp-p

NDR-240-48: 150 mVp-p

Voltage Adjustment Range

NDR-120-24: 24 to 28 VDC

NDR-120-48: 48 to 55 VDC

NDR-240-48: 48 to 55 VDC

Setup/Rise Time at Full Load

NDR-120-24: 2500 ms, 60 ms at 115 VAC

NDR-120-24: 1200 ms, 60 ms at 230 VAC

NDR-120-48: 2500 ms, 60 ms at 115 VAC

NDR-120-48: 1200 ms, 60 ms at 230 VAC

NDR-240-48: 3000 ms, 100 ms at 115 VAC

NDR-240-48: 1500 ms, 100 ms at 230 VAC

 

Typical Hold Up Time at Full Load

NDR-120-24: 10 ms at 115 VAC

NDR-120-24: 16 ms at 230 VAC

NDR-120-48: 10 ms at 115 VAC

NDR-120-48: 16 ms at 230 VAC

NDR-240-48: 22 ms at 115 VAC

NDR-240-48: 28 ms at 230 VAC

 

 

Input Power Parameters

Typical Efficiency

NDR-120-24: 88%

NDR-120-48: 89%

NDR-240-48: 90%

Typical Current

NDR-120-24: 1.3A @ 230 VAC, 2.25 A @ 115 VAC

NDR-120-48: 1.3A @ 230 VAC, 2.25 A @ 115 VAC

NDR-240-48: 1.3A @ 230 VAC, 2.5A @ 115 VAC

Voltage Range

90 to 264 VAC (47 to 63 Hz)

127 to 370 VDC

Inrush Current (cold start)

35A @ 230 VAC, 20A @ 115VAC

 

Overload Protection

Rated Output Power

105 to 160%

Protection Type

Constant current limiting, recovers automatically after fault condition is removed

 

Overvoltage Protection

Overvoltage Range

NDR-120-24: 29 to 33 V

NDR-240-48: 56 to 65 V

NDR-120-48: 56 to 65 V

Protection Type

Shut down operating voltage, repower on to recover

 

Physical Characteristics

Housing

Metal

Dimensions

NDR-120-24: 123.75 x 125.20 x 40 mm (4.87 x 4.93 x 1.57 in)

NDR-120-48: 123.75 x 125.20 x 40 mm (4.87 x 4.93 x 1.57 in)

NDR-240-48: 127.81 x 123.75 x 63 mm (5.03 x 4.87 x 2.48 in)

Weight

NDR-120-24: 500g (1.10lb)

NDR-120-48: 500g (1.10lb)

NDR-240-48: 900 g (1.98 lb)

 

Environmental Limits

Operating Temperature

NDR-120-24: -20 to 65°C (-4 to 149°F)

NDR-120-48: -20 to 65°C (-4 to 149°F)

NDR-240-48: -20 to 70°C (-4 to 158°F)

Storage Temperature

-40 to 85°C (-40 to 185°F)

Ambient Relative Humidity

20 to 95% (non-condensing)

Max. Operating Temperature at Full Load

NDR-120-48: 45°C (113°F)

NDR-120-24: 45°C (113°F)

NDR-240-48: 50°C (122°F)

 

Moxa NDR-120-24 Available Models

Model 1

Moxa NDR-120-24

Model 2

Moxa NDR-120-48

Model 3

Moxa NDR-240-48

 

 

Hot Tags: moxa ndr-120-24, China, wholesale, online, order, eds p206a 4poe, eds 308 ss sc, moxa e1241, Moxa IMC-21A-M-SC, Moxa IMC-21A-S-SC-T, uport1100