Hirschmann EAGLE20-0400999TT999SCCZ9HSEOP Hirschmann EAGLE20 Industrial Firewalls
Configurator Description
Hirschmann EAGLE20 multiport industrial firewalls, paired with the advanced security functionality of the Hirschmann Security Operating System (HiSecOS), create a solution capable of securing and protecting an entire industrial network.
Technical Specifications
Product description
|
Description |
Industrial firewall and security router, DIN rail mounted, fanless design. Fast Ethernet type. |
|
Port type and quantity |
4 ports in total, Ports Fast Ethernet: 4 x 10/100BASE TX / RJ45 |
More Interfaces
|
V.24 interface |
1 x RJ11 socket |
|
SD-card slot |
1 x SD card slot to connect the auto configuration adapter ACA31 |
|
USB interface |
1 x USB to connect auto-configuration adapter ACA22-USB |
|
Digital Input |
1 x plug-in terminal block, 2-pin |
|
Power Supply |
2 x plug-in terminal block, 2-pin |
|
Signaling contact |
1 x plug-in terminal block, 2-pin |
Network size - length of cable
|
Twisted pair (TP) |
0-100 m |
Network size - cascadibility
|
Line - / star topology |
any |
Power requirements
|
Operating Voltage |
2 x 24/36/48 VDC (18 -60VDC) |
|
Power consumption |
12 W |
|
Power output in BTU (IT)/h |
41 |
Security features
|
Multipoint VPN |
IPSec VPN |
|
Deep Packet Inspection |
Enforcer "OPC Classic" |
|
Stateful inspection firewall |
Firewall rules (incoming/outgoing, management); DoS prevention |
Software
|
Redundancy |
VRRP (Virtual Router Redundancy Protocol); VRRP Tracking |
|
Management |
SNMPv3; SSH2/SFTP/SCP; HTTP; HTTPS; V.24 CLI; SNMPv1/2, Traps; local and central user management (RADIUS); HiDiscovery; Industrial HiVision; HiView; ; Dual Software Image Support; LLDP (802.1AB); |
|
Diagnostics |
LEDs (power, link status, data, status, ACA, RM); signal contact (DC 24 V / 1 A); logfile; syslog; configuration check; RMON (statistics); SFP diagnostics (temperature, optical transmit and receive power); trap for changes and configuration saves; Counter for ACL Rules Verbose syslog with traffic information |
|
Configuration |
Command Line Interface (CLI); web interface; Auto Configuration Adapter (ACA22, ACA31); HiDiscovery; Industrial HiVision; Automatic Configuration Undo (roll-back); Configuration Fingerprint; Text-based Configuration File (XML); CLI Scripting; Full-featured MIB Support; |
|
Security |
Layer 3 and Layer 2 Access Control Lists (ACL); ACL flow based limiting; Audit trail; HTTPS; SSHv2; SFTP; SNMPv3; Management VLAN; Role based Access Control; Remote Authentication via RADIUS; IEEE1686 compliant configuration possible; Ingress storm protection, Password change on first login |
|
Time synchronisation |
Buffered Real Time Clock, NTP Client, NTP Server |
|
Miscellaneous |
Support for WAN Interface SHDSL; Support for FE/GE Twisted Pair SFP; Wire speed port scan prevention; 8 QoS classes; port prioritization IEEE 802.1D/Q; VLAN IEEE 802.1Q, DHCP relay |
|
Routing |
VLAN and port based routing; static routing; multinetting; IP masquerading; 1-to-1 NAT; port forwarding; Static and Dynamic ARP enteries; OSPFv2; Static Route Tracking |
Ambient conditions
|
Operating temperature |
0-+60 °C |
|
Storage/transport temperature |
-40-+85 °C |
|
Relative humidity (non-condensing) |
10-95 % |
Mechanical construction
|
Dimensions (WxHxD) |
90 x 164 x 120mm |
|
Weight |
1200 g |
|
Mounting |
DIN Rail |
|
Protection class |
IP20 |
Mechanical stability
|
IEC 60068-2-6 vibration |
1 mm, 2 Hz-13.2 Hz, 90 min.; 0.7 g, 13.2 Hz-100 Hz, 90 min.; 3.5 mm, 3 Hz-9 Hz, 10 cycles, 1 octave/min.; 1 g, 9 Hz-150 Hz, 10 cycles, 1 octave/min |
|
IEC 60068-2-27 shock |
15 g, 11 ms duration, 18 shocks |
EMC interference immunity
|
EN 61000-4-2 electrostatic discharge (ESD) |
8 kV contact discharge, 15 kV air discharge |
|
EN 61000-4-3 electromagnetic field |
35 V/m (80 - 3000 MHz); 1kHz, 80% AM |
|
EN 61000-4-4 fast transients (burst) |
4 kV power line, 4 kV data line |
|
EN 61000-4-5 surge voltage |
power line: 2 kV (line/earth), 1 kV (line/line); data line: 1 kV; IEEE1613: power line 5kV (line/earth) |
|
EN 61000-4-6 Conducted Immunity |
10 V (150 kHz-80 MHz) |
|
EN 61000-4-16 mains frequency voltage |
30 V, 50 Hz continous; 300 V, 50 Hz 1 s |
EMC emitted immunity
|
EN 55032 |
EN 55032 Class A |
|
FCC CFR47 Part 15 |
FCC 47CFR Part 15, Class A |
Approvals
|
Basis Standard |
CE; FCC; EN 61131; EN 60950 |
Scope of delivery and accessories
|
Accessories |
Rail power supply RPS 30, RPS 80 EEC, RPS 120 EEC, terminal cable, network management Industrial HiVision, auto-configuration adpater ACA22-USB EEC or ACA31, 19" installation frame |
|
Scope of delivery |
Device, terminal blocks , General safety instructions |
Further Instructions
|
Product Documentation |
https://www.doc.hirschmann.com/index.html |
|
Certificates |
https://www.doc.hirschmann.com/certificates.html |